Hard drives and SSDs usually give warning signs before they fail completely: reallocated sectors, read errors, wear levels approaching their limit. SMART (Self-Monitoring, Analysis and Reporting Technology) records these inside the drive, and smartctl reads them. On a dedicated server, checking SMART is how you catch a dying disk while RAID can still save your data.

On a VPS, the virtual disk doesn’t expose SMART data. The provider monitors the physical hardware. This guide applies to dedicated servers and your own hardware.

Install smartmontools

sudo apt install smartmontools      # Debian/Ubuntu
sudo dnf install smartmontools      # RHEL family

List the drives:

sudo smartctl --scan
lsblk -d -o NAME,SIZE,MODEL,ROTA

ROTA=1 means a spinning hard disk, and 0 means SSD or NVMe. See lsblk.

Quick health verdict

sudo smartctl -H /dev/sda
# SMART overall-health self-assessment test result: PASSED

PASSED only means the drive hasn’t crossed the manufacturer’s failure thresholds. Many drives fail while still reporting PASSED, so look at the attributes too.

Full report

sudo smartctl -a /dev/sda          # SATA/SAS
sudo smartctl -a /dev/nvme0        # NVMe
sudo smartctl -x /dev/sda          # extended (more logs)

Drives behind hardware RAID controllers need a device type: -d megaraid,0, -d cciss,0 and so on. Check your controller’s documentation.

SATA/SAS attributes that matter

ID Attribute Worry when
5 Reallocated_Sector_Ct Above 0 and growing
187 Reported_Uncorrect Above 0
188 Command_Timeout Climbing
197 Current_Pending_Sector Above 0 (sectors waiting to be remapped)
198 Offline_Uncorrectable Above 0
199 UDMA_CRC_Error_Count Climbing (often a cable or backplane issue, not the disk)
9 Power_On_Hours Context: age of the drive
194 Temperature_Celsius Consistently above ~50–55 °C

Look at the RAW_VALUE column for counts. The normalised VALUE/WORST/THRESH columns are vendor-scaled.

For SSDs, also check wear indicators such as Wear_Leveling_Count, Media_Wearout_Indicator or Percent_Lifetime_Remain. Names vary by vendor.

NVMe health

sudo smartctl -a /dev/nvme0

Key lines:

Critical Warning:                   0x00
Temperature:                        41 Celsius
Available Spare:                    100%
Percentage Used:                    7%
Media and Data Integrity Errors:    0
Unsafe Shutdowns:                   12
  • Critical Warning should be 0x00.
  • Percentage Used is the wear estimate. 100% means the rated endurance has been used, though drives often keep working beyond it.
  • Available Spare falling towards its threshold, or Media Errors above 0, mean it’s time to plan a replacement.

nvme smart-log /dev/nvme0 (from nvme-cli) shows the same data.

Run self-tests

sudo smartctl -t short /dev/sda      # ~2 minutes
sudo smartctl -t long /dev/sda       # hours on large HDDs; runs in the background
sudo smartctl -l selftest /dev/sda   # results

A failed self-test, with “read failure” and an LBA, is a strong signal to replace the drive.

Continuous monitoring with smartd

smartd watches drives in the background and alerts you. Edit /etc/smartd.conf (Debian/Ubuntu) or /etc/smartmontools/smartd.conf (RHEL):

DEVICESCAN -a -o on -S on -n standby,q -s (S/../.././02|L/../../6/03) -W 4,45,55 -m [email protected]
  • -a — monitor all attributes.
  • -s (S/../.././02|L/../../6/03) — a short test daily at 02:00 and a long test on Saturdays at 03:00.
  • -W 4,45,55 — report temperature changes of 4 °C, and warn at 45 °C and 55 °C.
  • -m — the email address. It needs a working local mail setup (Postfix or msmtp).
sudo systemctl enable --now smartd     # 'smartmontools' service on some Debian versions

Monitoring systems like Netdata and Prometheus’ smartctl exporter can graph SMART values and alert too. See Netdata.

When a drive shows problems

  1. Check that backups are current. Do it now, before anything else. See the 3-2-1 rule.
  2. Check RAID status: cat /proc/mdstat or zpool status. See mdadm and ZFS.
  3. Note the drive’s serial number (smartctl -i /dev/sda) so the right physical disk is replaced.
  4. On a dedicated server, open a support ticket with the SMART output and serial number to request a drive replacement.
  5. After the swap, rebuild the RAID and verify it.

Also check kernel logs for I/O errors. See dmesg.

Quick reference

Task Command
List drives smartctl --scan
Health verdict smartctl -H /dev/sda
Full report smartctl -a /dev/sda
NVMe smartctl -a /dev/nvme0
Short / long test smartctl -t short|long /dev/sda
Test results smartctl -l selftest /dev/sda
Serial number smartctl -i /dev/sda
Monitoring daemon smartd

Related: iostat and Linux disk performance.

  • Linux